  Datasheet File OCR Text:
  input parameter conditions min. typ. max. units input voltage range switch selectable 88 115 132 vac 176 220 264 248 370 vdc input frequency 47 63 hz input current see model selection guide inrush current cold start, 115 vac 30.0 a pk cold start, 230 vac 60.0 safety ground leakage current 115 vac 0.7 ma 240 vac 1.0 output parameter conditions min. typ. max. units output voltage see model selection guide output current see model selection guide output voltage adjustment see model selection guide output voltage tolerance, see note 1 see model selection guide ripple & noise (20 mhz), see note 2 see model selection guide hold-up time 115 vac 15 msec 230 vac 20 set-up time 230 vac 1,000 msec rise time 230 vac 30 msec temperature coef cient ?.02 %/? short circuit protection continuous (autorecovery) over voltage protection see note 3 115 135 % overload protection see note 4 135 165 % general parameter conditions min. typ. max. units isolation voltage input to output 3,000 vac input to ground 1,500 output to ground 500 isolation resistance 500 vdc 100 m emi/rfi conducted en 55022; en 61000-3-2, -3 emc compliance electrostatic discharge (esd) iec/en 61000-4-2, -6, -8, -11 rf field susceptibility iec/en61000-4-3 electrical fast transients/bursts on mains iec/en 61000-4-4 surge iec/en 61000-4-5 switching frequency 75 khz environmental parameter conditions min. typ. max. units operating temperature range ambient -10 +25 +60 ? storage temperature range -20 +85 ? cooling free air convection humidity rh, non-condensing 95 % physical case size 7.83 x 3.86 x 1.50 inches (199.0 x 98.0 x 38.0 mm) case material vented metal enclosure weight 22.9 oz (0.65 kg) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 300 khours safety standards can/csa-c22.2 no 60950-1-03, ansi/ul std no 60950-1, iec 60950 vibration 10~500 hz, 2g 10 min/1 cycle. period of 60 min each along x, y &z axis micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com single output, 100w compact, enclosed ac/dc power supplies key features: 100w output power selectable 88-264 ac input en60950 approved wide temp operation seven single output models meets en55022 >300 khour mtbf compact metal enclosure s il o t t 1 0 0 w mpe-100fs series rohs compliant electrical speci cations speci? cations typical @ +25c, nominal input voltage & rated output current, unless otherwise noted. speci? cations subject to change without notice.
model selection guide mechanical dimensions notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.01 ( 0.25) pin function 1 ac-line 2 ac-neutral 3 ac-ground 4 -vout 5 -vout 6 +vout 7 +vout pin connections micropower direct www.micropowerdirect.com 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com model number input output output tolerance (%) ripple & noise (mv p-p) ef ciency (%, typ) current (a) voltage (vdc) current (a) 115 vac 230 vac rated adjust rated range MPE-100FS-05 3.15 1.5 5.0 4.5 - 5.5 20.0 0 to 20.0 ?.0 100 76 mpe-100fs-7.5 3.15 1.5 7.5 6.75 - 8.25 13.5 0 to 13.5 ?.0 125 78 mpe-100fs-12 3.15 1.5 12.0 10.8 - 13.2 8.5 0 to 8.5 ?.0 125 80 mpe-100fss-15 3.15 1.5 15.0 13.5 - 16.5 6.7 0 to 6.7 ?.0 125 81 mpe-100fs-24 3.15 1.5 24.0 21.6 - 26.4 4.5 0 to 4.5 ?.0 150 83 mpe-100fs-27 3.15 1.5 27.0 24.3 - 29.7 3.5 0 to 3.5 ?.0 150 83 mpe-100fs-48 3.15 1.5 48.0 43.2 - 52.8 2.2 0 to 2.2 ?.0 150 84 derating curve static characteristics notes: 1. output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. ripple and noise is measured at 20 mhz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. a 0.1 f and a 47 f capaci- tor are connected in parallel as close to the power supply terminals as pos- sible. 3. overvoltage protection is provided by a ?iccup mode?circuit. the unit recovers automatically when the fault condition is removed. 4. the overload protection circuit shuts down the output. the unit recovers automatically when the fault condition is removed. 5. it is recommended that a fuse be used on the input of a power supply for protection. for the mpe-100fs series, a 7.5a/250 vac slow blow should be used.


▲Up To Search▲   

 
Price & Availability of MPE-100FS-05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X